CRACKS IN A FRAMED STRUCTURE
|
|
|
By gently removing the plaster around a crack confirm if it is a crack in the plaster, which is not dangerous. A crack in the
concrete may be confirmed by looking on all sides of the column or beam. This kind of crack must be immediately checked by a structural engineer.
|
|
|
DANGEROUS :
|
|
|
|
Diagonal crack in a column
|
|
|
Horizontal crack in a colum |

|
|

|
Diagonal crack in a cantilever beam must be checked. |
|
|
NON-DANGEROUS :
|
|
|
Cracks between the frame and the partition wall/infill wall and diagonal cracks in the partition walls of a framed structure. |

|
|

|
Cracks along or in the lintels of the openings (doors and windows) |
|
|
Crack between slab and parapet wall in balconies, terraces and stairs.
|

|
|
|

|
Settlement of ground around column
Crack in step or otlas at ground level only.
|
|
|
|
|
|
|
|
|
Disclaimer